-40%
Ccure Software House USTAR-GCM-2U ULTRA 19" ENCLOSURE ONLY New
$ 155.76
- Description
- Size Guide
Description
Ccure Software House USTAR-GCM-2U ULTRA19" ENCLOSURE ONLY
Condition is New, open box. Pink Document Holder as seen in pics, might vary, at minimum the Controller Document, as well as a pink envelope. The SW House CD may or may not be included. If its absolutely necessarry, please contact us and we can arranged to track down a copy.
If its not in any pictures, it will not be included.
This enclosure was left over after a customer changed their mind and wanted wall mounted enclosures instead of the rack mount version you see here.
Features That Make a Difference: • Powerful network-ready door controller for up to 32 readers (16 from ACMs) • Embedded lock power management lowers installation costs • Hardened Linux embedded OS for improved security and scalability • Includes global anti-passback and advanced peer-to-peer clustering • Native intrusion zone functionality • LCD provides important controller status and diagnostics information • Manages up to 500,000 cardholders in local memory • Dedicated input for fire alarm interlock overrides door locks during fire conditions • Onboard 256-bit AES network encryption • Tested and validated for FIPS 140-2 under the National Institute of Standards and Technology (NIST) Cryptographic Module Validation Program • Compatible with C•CURE 9000 v2.30 and above2 • Enables ASSA ABLOY Aperio or Schlage AD300 and AD400 wireless locks to communicate with C•CURE 9000 providing a fully integrated and managed lock solution • Rack-mount models provide flexibility in mounting options • Great solution for enterprise and government installations iSTAR Ultra Access Controller for up to 32 Readers1 iSTAR Ultra is a powerful, network-ready controller that supports up to 32 readers1 . The strong feature set answers the most demanding access control requirements of enterprise and government applications. Rack-mount and wall-mount options provide installation flexibility, while iSTAR Ultra’s unique lock power management eliminates the need for separate lock power interface boards. iSTAR Ultra features a hardened Linux kernel for its operating system, improving the security and scalability of the system. Supports up to 32 Readers iSTAR Ultra uniquely combines support for traditional hard-wired access control doors with support for wireless lock sets, all in the same controller. Up to 32 readers are supported by the iSTAR Ultra, of which 16 may come from the Access Control Module’s (ACM) I/O units – the rest can be made up of wireless lock sets and devices. iSTAR Ultra is ideal for areas that require many readers in close proximity to the panel. For more distributed installations, iSTAR Ultra includes up to 16 RS-485 ports, allowing the installer to run longer distances to each door. iSTAR Ultra uses a General Controller Module (GCM) which includes standard 2GB RAM and 16GB SD card for memory, and has two onboard gigabit network ports for reliable network communications. The GCM controls up to two ACMs, with each ACM supporting up to eight Wiegand or RM readers, along with 24 supervised inputs and 16 outputs which can be individually wet- or dry-configured. iSTAR Ultra also includes an alphanumeric LCD to provide status and troubleshooting information. Database backups and all buffered transactions are stored to non-volatile SD card memory. A real-time clock battery keeps the clock powered during a power failure. Network Ready iSTAR Ultra includes two onboard gigabit network ports for primary and secondary communications to the host. 256-bit FIPS 197 and FIPS 140-2 AES network encryption, with custom key management, secures the controller from potential network threats. iSTAR Ultra supports both static and dynamic IP addresses, using DHCP and DNS to simplify network installation. In addition, the powerful iSTAR Configuration Utility (ICU) reduces startup time by allowing you to view online controllers, change configuration parameters, and download new firmware from a single interfa
SpecificationsPhysicalDimensions (H x W x D)Wall-Mount . . . . . . . . . . . . . . 635 x 560 x 127 mm (25.0 x 22.0 x 5.0 in)Rack-Mount GCM . . . . . . . . . 86 x 445 x 252 mm (3.4 x 17.5 x 10 in)(2U rack height)Rack-Mount ACM . . . . . . . . . 175 x 445 x 125 mm (6.9 x 17.5 x 4.9 in)(4U rack height)GCM Board . . . . . . . . . . . . . . 165 x 266 x 26 mm (6.5 x 10.5 x 1.02 in)ACM Board . . . . . . . . . . . . . . 115 x 397 x 36 mm (4.5 x 15.7 x 1.4 in)WeightWall-Mount . . . . . . . . . . . . . . 12.3 kg (27 lbs)Rack-Mount GCM . . . . . . . . . 4.3 kg (9.5 lbs)Rack-Mount ACM . . . . . . . . . 4.1 kg (9.0 lbs)Enclosure Material . . . . . . . . . . . . 16 gauge carbon steel, with tamper switchEnvironmentalOperating Temperature . . . . . 0-50°C (32-122°F)Operating Relative Humidity . . 5-95% RH non-condensingStorage Temperature . . . . . . . -20-60°C (-4-140°F)ElectricalPower Requirements, GCM . . . . . 12 VDC +/- 20%, 0.5 A plus up to1.5 A per RS-485 portPower Requirements,Each ACM . . . . . . . . . . . . . . . . . . ACM board: 12 VDC +/- 20%, 0.5 A min, up to12 A max depending on power required ofconnected devices (readers, door modules,PIRs). ACM lock power (optional): 0-30 VDC, upto 12 A max (two lock power inputs per ACM)Heat Dissipation . . . . . . . . . . . . . . GCM: 61 BTU/hr, each ACM: 20.5 BTU/hrMemory and RTC Backup . . . . . . CR 2032 lithium battery provides RTC backup;database and buffered transactions stored innon-volatile memorySystem and NetworkCPU . . . . . . . . . . . . . . . . . . . . . . . Freescale i.MX6 1 GHz dual core Cortex-A9System Memory . . . . . . . . . . . . . . 2 GB RAMSD Storage . . . . . . . . . . . . . . . . . 16 GB SD cardPrimary Network Port . . . . . . . . . . 10/100/1000 Mbps, full duplex, auto-negotiateSecondary Network Port . . . . . . . 10/100/1000 Mbps, full duplex, auto-negotiateNetwork Encryption . . . . . . . . . . . Optional AES 256-bit, with custom keymanagementIndicators and Switches . . . . . . . . LCD for diagnostics, LEDs for power, LANactivity, serial port activity, output status,encryption-enable switchMemory Capacity5Ten clearances, five cards/person, 40-digit card . . . . . . . . . . 500,000 cardholdersTransaction Buffer Size . . . . . . . . . 10,000 minimum, 500,000 maximumInputs/Outputs, GCMDedicated Inputs . . . . . . . . . . . . . Cabinet tamper, AC fail, low batteryDistance, GCM to ACM . . . . . . . Up to 1.83 m (6 ft)Specifications for Wireless Lockset Support6Wireless LocksetTechnologies Supported . . . . . . . . ASSA ABLOY Aperio, Schlage AD300and AD400GCM RS485 Ports toConnect Wireless Hubs . . . . . . . . 2Max # of Locksetsper RS485 Port . . . . . . . . . . . . . . 16Max # of Wireless Hubsper RS485 Port . . . . . . . . . . . . . . 15 (Aperio), 16 (Schlage)Max # of Locksets perWirless Hub . . . . . . . . . . . . . . . . . 8 (Aperio), 16 (Schlage)Specifications per ACM Board7ReadersNumber of Readers Supported,per ACM Board . . . . . . . . . . . . . . 8Types of Readers Supported . . . . Wiegand and RM (RS-485)Reader TechnologiesSupported . . . . . . . . . . . . . . . . . . Multi-Technology, Proximity, Smart Card(incl. PIV II & TWIC), Wiegand, and MagneticStripe (RM only)Maximum Distance to Door . . . . . RM: 1,219 m (4,000 ft); Wiegand: 150 m (500 ft)Reader Power Available(dependent on power supply) . . . . 12 VDC, 1.5 A max per reader (including auxpower and RM port power)Reader Power Status Indication . . On/off indication per port, through C•CURE 9000RM Bus Communications . . . . . . . Eight ports, RS-485 half duplex, two wire, plusoptional two wires for device powerInputsNumber of General PurposeInputs per ACM . . . . . . . . . . . . . . 24, configurable supervision per inputAdditional Dedicated Inputs . . . . . cabinet tamper, fire alarm interlock, fire alarmkeyswitch override (supervision supported)Input Expansion . . . . . . . . . . . . . . Up to 128 additional inputs using I8 modules onRM busOutputsNumber of Relay Outputsper ACM . . . . . . . . . . . . . . . . . . . . 16 (eight for locking devices, eight for localannunciation)Output Power Feeds . . . . . . . . . . Two per ACM (L1 and L2), 0-30 VDC, 12 A max.Voltage value of each feed displayed throughC•CURE 9000Output Power Selection . . . . . . . . Individually configurable via jumper as powersourcing (wet, L1 or L2), or dry contact relayOutput Power (Wet) . . . . . . . . . . . Up to 0.75 A per lock. Voltage follows selectionof power feed (L1 or L2)Primary Lock Output Rating,Dry Contact . . . . . . . . . . . . . . . . . 0 to 30 VAC/DC, 5 A maxSecondary Output Rating,Dry Contact . . . . . . . . . . . . . . . . . 0 to 30 VAC/DC, 1 A maxOutput Protection . . . . . . . . . . . . . Individual PTC resettable fuse, snubber,transzorb, reverse polarity protection (primarylock outputs use socketed relays)Output Expansion . . . . . . . . . . . . . Up to 128 additional relay outputs usingR8 modules on RM busRegulatoryAccess Control . . . . . . . . . . . . . . . UL 294, CSA C22.2 No. 205 (Canada)Burglar Alarm . . . . . . . . . . . . . . . . UL 1076, ULc 1076 (Canada)CE . . . . . . . . . . . . . . . . . . . . . . . . EN 55022 (EMI), EN 55024 (EMC), EN 60950-1(Safety)Safety . . . . . . . . . . . . . . . . . . . . . . IEC 60950-1EMI . . . . . . . . . . . . . . . . . . . . . . . . FCC Part 15 Class A, EN 55022, ICES-003(Canada), VCCI Class A ITE (Japan), C-Tick(AS/NZS CISPR 22 - Australia/New Zealand)EMC . . . . . . . . . . . . . . . . . . . . . . . EN 55024, EN 50130-4, IEC 62599-2,EN 61000-6-1Encryption . . . . . . . . . . . . . . . . . . . FIPS 140-2 Level 2 (Certificate #2315), FIPS 197Seismic Certification . . . . . . . . . . . OSHPD Certification File # OSP-0425-10